Wittmann Tempro Plus D 360 Manual !!top!! – Direct

Includes automatic pressure monitoring to ensure internal pressure remains at least 1 bar above the steam pressure curve. Core Features & Functionality

Prevents the system from exceeding safe operating limits.

The is a pressurized water temperature controller designed to manage mold temperatures up to 160°C or higher in some configurations (using water as the medium). It is known for its ability to provide extremely precise temperature control, which is essential for ensuring product quality in injection molding. Key Features

After setting the setpoint, press . The unit performs a self-check: Wittmann Tempro Plus D 360 Manual

: To access settings and service menus, select the settings icon on the right side of the 5.7-inch color touch-screen and enter the default user password Startup & Filling

: The touch-screen uses a color-coded mold symbol to indicate status: for within tolerance, for too hot, and for too cold. WITTMANN Group Maintenance & Alarms Download Center - WITTMANN Group

If you need tailored, immediate help, I can help you: It is known for its ability to provide

Typically ranges from 9 kW to 36 kW depending on the specific sub-model configuration.

The mold began to sweat. Condensation droplets evaporated off the A-side. The D 360’s pump changed pitch—from a struggling cough to a smooth, powerful drone. The digital readout flickered: Set: 190°F / Actual: 188.6°F … 189.2°F … 190.0°F. It held. It locked.

Includes automatic filling, constant pressure monitoring, and sensor break monitoring. WITTMANN Group Maintenance & Alarms Download Center -

| Problem | Possible Cause | Solution | |----------------------|--------------------------------|-----------------------------------------------| | | PID settings incorrect | Run auto-tuning or reset to default PID values. | | Unit not heating | Heater relay failure | Check relay for welding; replace if necessary. | | Low pressure alarm | Water supply interruption | Ensure water supply is open and pressure is adequate. | | Error code E-01 | Sensor break or short circuit | Check temperature sensor and wiring; replace sensor. | | Unit shuts down randomly | Overheating due to poor cooling | Clean the cooling water filter and heat exchanger. | | Pump not running | Motor overload tripped | Reset the overload relay; check for blockage. |

Clean the factory water inlet filter. Verify that factory cooling water valves are open. Check contactor mechanical operation. Low Flow / No Flow Alarm

Ultimate Guide to the Wittmann Tempro Plus D 360 Temperature Control Unit

Required when handling mold connections, hoses, or internal plumbing.

Wittmann Tempro Plus D 360 Manual